RORCOL AV60
For aluminum composite pipes, metal pipes and cables
Logo - CE mark

Brief information

  • Classification: EI120/EI90
  • Dimensions: DN40 to DN160
  • Installation depth: 61 mm
  • Omega application: DN40 to DN80

Downloads

Installation Instructions and Declaration of Performance
Brochure
Wood Construction Brochure
Tender text

Other languages

English
Installation instructions
& DoP
Brochure
Timber Construction Brochure

 

French

& DoP Assembly Instructions
Brochure
Wood Construction Brochure

 

Dutch

& DoP Installation Guide
Brochure
Wooden Construction Brochure

 

Croatian
Installation instructions for
& DoP

 

Estonia

& DoP Installation Guide
Brošüür
Brochure on Wooden Structures

 

Latvian

& DoP Installation Instructions
Brošūra
Brochure on Wood Construction

 

In Lithuanian
Brochure on Wooden Structures

 

p

Special features

  • Housing made of NIROSTA
  • Integrated mounting bracket extension for bridging larger ring gaps
  • Twistable mounting brackets
  • Integrated positioning aid
  • Zero distance between the fire protection collars

Product description

The RORCOL AV60 fire protection collar is used to seal off aluminum composite pipes, metal pipes, electrical installation pipes and cables.

It consists of a stainless steel housing with an internal intumescent layer. Due to the different serration of the stainless steel housing, the RORCOL AV60 and RORCOL V30/V60 fire protection sleeves can be distinguished and assigned to the intended area of application. The mounting brackets are used to fasten the fire protection collar, which can be rotated by up to 45° if space is limited. The integrated mounting lug extension allows them to be extended by 15 mm. The RORCOL AV60 fire protection collar is closed using a locking system, which is used for fastening when installed as an omega application. When using formwork in ceilings, positioning the fire protection collar is made easier by folding out the integrated positioning aids.

Functionality

In the event of fire, the intumescent inside the stainless steel housing expands. This limits the heat transfer to the side facing away from the fire in the case of aluminum composite pipes, metal pipes and cables.

Further information

Permitted separating components

Distance regulation

 

Size chart

Item no.TypeNominal sizeVE
9505040 BRM/AV60/DN16-40 16-40 mm 30
9505056 BRM/AV60/DN50-56 50-56 mm 21
9505063 BRM/AV60/DN59-63 59-63 mm 15
9505080 BRM/AV60/DN75-80 75-80 mm 9
9505110 BRM/AV60/DN110 110 mm 5
9505125 BRM/AV60/DN125 125 mm 5
9505140 BRM/AV60/DN140 140 mm 16
9505160 BRM/AV60/DN160 160 mm 10
Product - RORCOL AV60 fire protection collar

RORCOL AV60